Unterschiede hervorheben | 960 GB SAS SSD Samsung PM1643a |
1,92 TB SAS SSD Samsung PM1643a |
3,84 TB SAS SSD Samsung PM1643a |
7,68 TB SAS SSD Samsung PM1643a |
15,36 TB SAS SSD Samsung PM1643a |
1,92 TB Enterprise SAS SSD KIOXIA PM7-R Series |
3,84 TB Enterprise SAS SSD KIOXIA PM7-R Series |
7,68 TB Enterprise SAS SSD KIOXIA PM7-R Series |
15,36 TB Enterprise SAS SSD KIOXIA PM7-R Series |
30,72 TB Enterprise SAS SSD KIOXIA PM7-R Series |
1,6 TB Enterprise SAS SSD KIOXIA PM7-V Series |
3,2 TB Enterprise SAS SSD KIOXIA PM7-V Series |
6,4 TB Enterprise SAS SSD KIOXIA PM7-V Series |
12,8 TB Enterprise SAS SSD KIOXIA PM7-V Series |
Hersteller | Samsung | Samsung | Samsung | Samsung | Samsung | KIOXIA | KIOXIA | KIOXIA | KIOXIA | KIOXIA | KIOXIA | KIOXIA | KIOXIA | KIOXIA |
Kapazität (GB) | 960 GB | 1,92 TB | 3,84 TB | 7,68 TB | 15,36 TB | 1,92 TB | 3,84 TB | 7,68 TB | 15,36 TB | 30,72 TB | 1,6 TB | 3,2 TB | 6,4 TB | 12,8 TB |
IOPS (lesen/schreiben) | 380000 / 40000 | 430000 / 60000 | 450000 / 90000 | 400000 / 90000 | 400000 / 65000 | 720000 / 155000 | 720000 / 155000 | 720000 / 175000 | 720000 / 160000 | 720000 / 80000 | 720000 / 320000 | 720000 / 340000 | 720000 / 355000 | 720000 / 330000 |
Lesen (MB/s) | 2100 | 2100 | 2100 | 2100 | 2100 | 4200 | 4200 | 4200 | 4200 | 4150 | 4200 | 4200 | 4200 | 4200 |
Schreiben (MB/s) | 1000 | 1800 | 2000 | 2000 | 1800 | 3400 | 3650 | 4100 | 4100 | 3200 | 3400 | 3650 | 4100 | 4100 |
Zellentyp | 64-Layer V-NAND TLC | 64-Layer V-NAND TLC | 64-Layer V-NAND TLC | 64-Layer V-NAND TLC | 64-Layer V-NAND TLC | 112-Layer BiCS FLASH™ TLC | 112-Layer BiCS FLASH™ TLC | 112-Layer BiCS FLASH™ TLC | 112-Layer BiCS FLASH™ TLC | 112-Layer BiCS FLASH™ TLC | 112-Layer BiCS FLASH™ TLC | 112-Layer BiCS FLASH™ TLC | 112-Layer BiCS FLASH™ TLC | 112-Layer BiCS FLASH™ TLC |
Controller | BiCS FLASH™ | BiCS FLASH™ | BiCS FLASH™ | BiCS FLASH™ | BiCS FLASH™ | BiCS FLASH™ | BiCS FLASH™ | BiCS FLASH™ | BiCS FLASH™ | |||||
Haltbarkeit (lebenslange Schreibzugriffe in TB) | 1752 TBW | 3504 TBW | 7008 TBW | 14016 TBW | 28032 | 3504 | 7008 | 14016 | 28032 | 56064 | 8760 | 17520 | 35040 | 70080 |
Full Drive Writes per Day | 1 DWD | 1 DWD | 1 DWD | 1 DWD | 1 DWD | 1 DWD | 1 DWD | 1 DWD | 1 DWD | 1 DWD | 3 DWD | 3 DWD | 3 DWD | 3 DWD |
Zuverlässigkeit (MTBF in Stunden) | 2.000.000 | 2.000.000 | 2.000.000 | 2.000.000 | 2.000.000 | 2.500.000 | 2.500.000 | 2.500.000 | 2.500.000 | 2.500.000 | 2.500.000 | 2.500.000 | 2.500.000 | 2.500.000 |
Power Loss Data Protection | ja | ja | ja | ja | ja | ja | ja | ja | ja | ja | ja | ja | ja | ja |
Leistungsaufnahme - aktiv (Watt) | 12,5W | 12,5W | 12,5W | 12,5W | 12,5W | 18,0W | 18,0W | 18,0W | 18,0W | 18,0W | 18,0W | 18,0W | 18,0W | 18,0W |
Schnittstelle | Dual SAS 12Gb/s | Dual SAS 12Gb/s | Dual SAS 12Gb/s | Dual SAS 12Gb/s | Dual SAS 12Gb/s | SAS4 24Gb/s | SAS4 24Gb/s | SAS4 24Gb/s | SAS4 24Gb/s | SAS4 24Gb/s | SAS4 24Gb/s | SAS4 24Gb/s | SAS4 24Gb/s | SAS4 24Gb/s |
Bauform | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll | 2,5 Zoll |